Hyaluronic acid sterilization: heat treatment and preservation of the molecular weight
titre
Steriflow proposed to the company Contiproan optimal solution for the sterilization of hyaluronic acid, product of the pharmaceutical industry. After several laboratory tests, we were able to propose a solution adapted to the sterilization requirements of this product.
The Contipro company in the Czech Republic contacted us following a first meeting at the Achema fair in Germany in 2009. Contipro used until now a competitor's saturated steam autoclave for the sterilization of hyaluronic acid in small vials (2 to 6 ml) for the pharmaceutical industry. But this autoclave did not give them satisfaction and Contipro wanted to know if another process (superheated cascading water) could give them better results for the sterilization of their products.
Why is sterilization of hyaluronic acid particularly complex?
Hyaluronic acid is used in the pharmaceutical industry and for industrial cosmetics. It is a very viscous product which has the peculiarity of losing its viscosity when exposed to high temperatures (+ 100 ° C). However, this product must necessarily be sterilized before its use (the sterilizing value sought is greater than 15mn), while optimizing the conservation of its molecular weight.
Sterilization tests of the product in our laboratory until the solution for our customer.
The solution of the autoclave with preheating
The use of an autoclave with a preheating ballast water shortens the CUT* (Come Up Time) phase. The sterilization process could, with our autoclaves, begin with water heated up to 140° C. But this solution was costly and during the project we have been competing with a company whose autoclave proposed a duration of CUT hypothetically shorter than standard Steriflow. * CUT: phase of elevation of the temperature which leads to a phase of constant temperature.
The beginning of the tests in our laboratory to propose the best sterilization solution
At this level of the project, we decided to propose to the customer tests on the sterilization of the product in our laboratory in Roanne. Two tests were carried out with our autoclaves cascading water: one with then the other without preheating of ballast water.
To our surprise, the results were identical with or without preheating and in all cases better than in the air / steam autoclave used until now by Contipro. We therefore had stronger viscosity of hyaluronic acid after sterilization, the only possible explanation of which was that the product cooled more rapidly in Steriflow to cascading water than in air / steam autoclave. The most critical phase for the preservation of the molecular weight and viscosity of the product was therefore not the heating phase but the cooling phase.
A thermal performance adapted to the sterilization of hyaluronic acid
This has enabled us to prove that the used in our autoclaves allows a shorter cooling phase than the air / steam autoclaves and particularly adapted to this application.
View video of our static autoclave with water runoff : https://www.youtube.com/watch?v=bWD87VVtzKU
- December 2020 (3)
- October 2020 (2)
- September 2020 (2)
- August 2020 (1)
- July 2020 (3)
- June 2020 (2)
- April 2020 (1)
- February 2020 (1)
- January 2020 (1)
- December 2019 (1)
- November 2019 (3)
- October 2019 (4)
- September 2019 (1)
- August 2019 (1)
- June 2019 (4)
- April 2019 (1)
- March 2019 (3)
- February 2019 (3)
- January 2019 (5)
- November 2018 (1)
- October 2018 (5)
- September 2018 (6)
- August 2018 (1)
- July 2018 (1)
- June 2018 (1)
- May 2018 (4)
- April 2018 (1)
- February 2018 (2)
- January 2018 (4)
- November 2017 (3)
- October 2017 (4)
- September 2017 (2)
- August 2017 (3)
- July 2017 (1)
- June 2017 (3)
- May 2017 (2)
- April 2017 (4)
- March 2017 (6)
- February 2017 (2)
- January 2017 (1)
- December 2016 (2)
- November 2016 (1)
- September 2016 (7)
- August 2016 (7)
- July 2016 (13)
- June 2016 (5)
- May 2016 (1)
- February 2016 (4)
- January 2016 (13)
- December 2015 (2)
- March 2015 (1)